Mindray PM-60 Pulse Oximeter | Spot-check & Continuous, 96h Trending
| MPN Code: | PM-60 |
The Mindray PM-60 is a portable pulse oximeter designed for spot-check & continuous monitoring of SpO2 and pulse rate, suitable for adult, pediatric & neonatal users.
Features (Mindray PM-60)
By selecting spot-check or continuous mode, you can match the device to quick checks or longer monitoring sessions.
In spot-check mode, workflow is supported with patient ID handling and power-saving functions such as auto-standby & auto power-off during idle time.
In continuous mode, the device supports pleth waveform display and practical alarm management during monitoring.
The 2.4" color display presents the key readings clearly, while adjustable brightness helps adapt visibility to different environments.
For record keeping, stored data can be exported to a PC via infrared communication when used with a compatible cable/kit.
Power options include Li-ion or AA batteries, allowing flexibility based on runtime needs and availability.
The unit is compact & lightweight, supporting easy transport and use across different care settings.
Technical Specifications
- Manufacturer: Mindray (Shenzhen Mindray Bio-Medical Electronics Co., Ltd.)
- Model: PM-60
- Dimensions: 55(W) × 120(H) × 30(D) mm
- Weight: up to 300 g (with battery)
- Display: 2.4" color TFT
- Display resolution: 320 × 240
- Parameters: SpO2 & Pulse Rate
- Operating modes: spot-check mode & continuous monitoring mode
- Waveform: 1 plethysmogram waveform (in waveform display)
- Memory (continuous): up to 96 hours of trending (2 s resolution) for a single patient
- Memory (spot-check): up to 4,000 sets of data for up to 99 patient IDs
- Alarms: adjustable high & low limits, visual & audible alarms (multi-level)
- Data transfer: infrared interface for PC export (with compatible cable/kit)
- Power options: Li-ion or 3 × AA alkaline
- Battery runtime: up to 36 hours of continuous operation (depending on batteries/settings)
- DC power: 5 VDC, 1.2 A
- Ingress protection: IPX2
- Standards & certifications: IEC 60601 series compliance & CE marking (per manufacturer documentation), ISO 10993 referenced for sensor biocompatibility where applicable
- MPN: not available
- GTIN: not available
Frequently Asked Questions (FAQ)
When should I use spot-check versus continuous mode on the PM-60?
Spot-check is designed for quick readings and efficient day-to-day checks, while continuous mode is useful when you need trending data and waveform display during longer monitoring periods.
How do memory and patient IDs help with day-to-day record keeping?
In spot-check mode, the PM-60 supports storing multiple records across patient IDs, and in continuous mode it keeps a longer trend history for a single patient, which helps when maintaining structured logs.
What is required for PC data export, and what is a practical tip before exporting?
PC export uses the infrared interface with a compatible cable/kit, and it is good practice to confirm records are properly stored before exporting, especially when the device is shared across shifts or locations.